行业新闻

Yuming Valve Knowledge Hub | Structural Characteristics of Gate Valves

2022.09.29
yuming


Gate valves are shut-off valves, and their sealing performance is generally inferior to that of globe valves. The primary function of a gate valve is to "cut off flow" with minimal flow resistance. When fully open, the flow path of a gate valve is straight-through, resulting in the lowest possible pressure loss. Its main advantage lies in the minimal flow resistance, with an average flow resistance coefficient of approximately 0.08 to 0.12. Gate valves are best suited for applications where the valve is kept either fully open or fully closed and where frequent operation is not required. They are not ideal for regulating or throttling purposes, as prolonged use in such conditions may lead to erosion and wear of the sealing surfaces, compromising the valve's sealing performance.

The medium's temperature and pressure, along with operational reliability, should be carefully considered when selecting gate valves.




During the opening and closing process, the sealing surfaces of the gate (valve disc) and the seat are in constant contact and subject to friction, making them prone to wear. This is particularly critical when the valve is near the closed position, as the pressure differential across the valve disc is substantial, resulting in accelerated wear of the sealing surfaces. Gate valves possess a degree of self-sealing capability, where the valve disc is tightly pressed against the seat by the medium's pressure, ensuring a tight seal.

The wedge-shaped gate valve typically has a disc angle of 3–6 degrees. If excessive force is applied during closure or if significant temperature variations occur, the valve disc may become stuck. Consequently, high-temperature and high-pressure wedge gate valves are often designed with features to prevent disc seizure.

When fully open, the flow path of the gate valve is completely unobstructed, ensuring minimal pressure loss. Its low flow resistance makes it an optimal choice for applications where the valve remains either fully open or fully closed. However, gate valves are not suitable for flow regulation or throttling purposes.