行业新闻

Yuming Valve Knowledge Hub | Working Principles of Balancing Valves

2023.03.21
yuming



Balancing valves are specialized valves designed to achieve both dynamic and static hydraulic balancing in a system. They can be classified into three main types: static balancing valves, dynamic balancing valves, and pressure-independent balancing valves.

A static balancing valve, also known as a manual balancing valve, digital locking balancing valve, or dual-position regulating valve, adjusts the flow resistance by altering the gap (opening) between the valve plug and seat. This change modifies the valve's flow coefficient (Kv), thus regulating the flow rate. Its primary function is to balance the system's resistance and eliminate imbalances, ensuring that water is distributed proportionally according to the design calculations. Static balancing valves can be installed in main pipes, risers, horizontal branches, or terminal points, performing similarly to an equal-length pipe.



Structural and Operational Principles of Balancing Valves


Balancing valves are not fundamentally different from other valves in structure but serve a unique function in specific applications. In certain industries, significant pressure or flow differences may exist across different sections of a pipeline or container. To reduce or balance these differences, valves are installed to regulate the relative pressure balance or achieve flow equilibrium through diversion. These valves are known as balancing valves.

Flow Characteristics

Balancing valves utilize a straight-through valve body design, offering better equal-percentage flow characteristics. This ensures reasonable flow distribution and effectively addresses uneven heating or cooling in HVAC systems.

System Adjustment and Locking

Once adjusted with intelligent instruments, the system's total water volume is locked within a reasonable range, eliminating the issue of "high flow, low temperature difference."

Resistance Adjustment

By adjusting the balancing valve, the ratio of system pipe resistance can be modified to meet design specifications.



Limitations in Centralized Control Systems

When the system relies on centralized flow regulation (e.g., pump speed adjustments), balancing valves and self-operated differential pressure balancing valves should not be used.

Suitability for Temperature-Based Control

In systems using temperature-based control, balancing valves and self-operated differential pressure balancing valves are applicable, as this method alters supply water temperature without affecting hydraulic conditions, ensuring consistent adjustment delivery to each user and device.

Absorbing Pressure Fluctuations

Balancing valves can absorb network pressure fluctuations and mitigate internal disturbances (e.g., changes in internal loop resistance), maintaining a constant differential pressure across controlled loops.

Challenges with Stage-Based Flow Regulation

For stage-based flow regulation, balancing valves may require frequent adjustments to control flow or differential pressure for each stage, complicating system management and making them less suitable.



Linear Flow Characteristics

With a constant pressure differential across the valve, the flow rate and valve opening maintain a roughly linear relationship.

Flow Distribution

Balancing valves ensure that the predetermined flow rate is achieved at various distribution points (e.g., each building unit).

Hydraulic Balancing with Intelligent Instruments

During hydraulic balancing, a soft hose connects the balancing valve’s test ports to a dedicated intelligent instrument, which displays the flow rate and pressure drop across the valve. By inputting the desired flow rate, the instrument calculates the required valve opening to achieve system balance.

Recalibration

All newly installed balancing valves and existing system loops should be recalibrated (except for branch balancing valves in existing loops). Proper hydraulic balancing in water circulation systems for HVAC and heating is crucial for efficient energy distribution.

Ensuring Flow Consistency

In HVAC and heating systems, chilled or heated media circulate through a closed piping system to each user. A well-designed network should allow all users to receive the design flow rate when terminal control valves (e.g., electric or thermostatic valves) are fully open. When control valve openings change, each user can adjust to the desired flow without interfering with others.