Causes of Internal Leakage in Ball Valves
1. Causes During Construction Phase:
Improper Transport and Handling: Damage to the valve during transport or lifting can result in internal leakage.
Post-Hydrostatic Testing: Failure to properly dry and apply anti-corrosion treatment after factory hydrostatic testing can lead to seal surface corrosion and leakage.
Inadequate On-Site Protection: Lack of blind flanges at valve ends allows contaminants like rainwater and sand to enter the valve seat, causing leakage.
Insufficient Lubrication: Failure to inject lubricant into the valve seat during installation may allow debris to enter the seat area, or welding damage may cause leakage.

Improper Installation Position: Not installing the valve in a fully open position during welding can result in ball damage. Weld spatter can adhere to the ball, damaging the valve seat during operation, leading to leakage.
Residual Weld Slag: Construction residues such as weld slag can scratch the sealing surface.
Incorrect Limit Adjustment: Factory or installation misalignment of the drive stem or related components may cause leakage.

2. Causes During Operation Phase:
Lack of Maintenance: Operators may neglect valve maintenance due to high costs or a lack of proper management practices, leading to premature failures.
Improper Operation: Failing to follow maintenance procedures can result in internal leakage.
Residual Debris: Construction debris during operation can scratch the sealing surface, causing leakage.
Improper Pipeline Cleaning: Incorrect pigging procedures can damage the sealing surface.
Inactivity: Prolonged disuse may cause the valve seat and ball to seize, resulting in sealing damage during operation.

Incomplete Valve Operation: Even a 2°–3° deviation from the fully open or closed position can cause leakage.
Stem Stop Block Contamination: Over time, rust, dust, or paint may accumulate between the valve stem and stop block, preventing full rotation and causing leakage. This issue is exacerbated in buried valves with extended stems, where additional debris may hinder proper valve operation.
Actuator Limit Issues: Corrosion, hardened grease, or loose limit bolts can lead to inaccurate actuator limits, resulting in internal leakage.
Improper Valve Positioning in Electric Actuators: Misconfigured valve positions in electric actuators can cause incomplete closure and leakage.
Lack of Periodic Maintenance: Dry or hardened sealing grease can accumulate behind the elastic valve seat, obstructing its movement and causing seal failure.

Methods for Detecting Internal Leakage in Natural Gas Ball Valves
In natural gas pipelines, trunnion-mounted ball valves are commonly used. The general inspection method involves rotating the valve to the fully open or closed position and using the valve body drain port to check for leaks. If the valve can be fully drained, the seal is intact. Continuous pressure discharge indicates leakage, requiring appropriate valve maintenance.