行业新闻

Yuming Valve Knowledge Hub | Causes and Solutions for Internal Leakage in Natural Gas Ball Valves

2023.12.22
yuming



Causes of Internal Leakage in Ball Valves


During Construction Phase


1.Improper Transportation and Handling: Damage to the valve during transport or lifting can result in internal leakage.

2.Inadequate Drying and Corrosion Protection: Failure to properly dry and protect the valve after hydrostatic testing at the factory can lead to sealing surface corrosion and subsequent leakage.

3.Insufficient On-Site Protection: Lack of blind plates at both valve ends allows rainwater, sand, and other debris to enter the valve seat, causing leaks.

4.No Lubrication During Installation: Failure to inject lubricant into the valve seat may result in debris entering the rear of the seat or damage during welding, leading to leakage.

5.Improper Valve Position During Installation: If the valve is not fully open during welding, weld spatter can damage the ball. This damage may worsen during valve operation, leading to seat damage and internal leakage.

6.Damage from Construction Residues: Welding slag or debris can scratch the sealing surface.

7.Incorrect Factory or Installation Limit Settings: Misalignment of the drive sleeve or other components with the valve stem can cause leakage.


During Operation Phase


1.Lack of Preventive Maintenance: Neglecting valve maintenance due to high costs or absence of a scientific maintenance approach can result in premature failure.

2.Improper Operation or Maintenance: Not following maintenance procedures can lead to leakage.

3.Residual Debris Scratching Sealing Surface: Construction residues during normal operation can damage the sealing surface.

4.Improper Cleaning: Incorrect pigging operations may damage the sealing surface, causing leakage.

5.Prolonged Inactivity: Failing to operate or maintain the valve for an extended period may lead to seat and ball adhesion, causing sealing damage during operation.

6.Incomplete Valve Opening or Closing: Even a 2°–3° deviation from the fully open or closed position can cause leakage.

7.Accumulated Rust and Debris: For large-diameter valves with stem stops, prolonged use may result in rust, dust, or paint buildup between the stem and stop, preventing full rotation and causing leakage. Underground valves with extended stems are especially prone to rust accumulation, further obstructing rotation.

8.Actuator Limit Issues: Corrosion, hardened grease, or loosened limit bolts in actuators may result in inaccurate limits, causing leakage.

9.Improper Electric Actuator Settings: Incorrect valve position settings in electric actuators may prevent full closure, leading to internal leakage.

10.Lack of Routine Maintenance: Dried and hardened sealing grease can accumulate behind the elastic seat, obstructing seat movement and leading to sealing failure.


Detection of Internal Leakage in Natural Gas Ball Valves


Fixed-shaft ball valves are commonly used in natural gas pipelines. A standard inspection method involves turning the valve to the fully open or closed position and checking for leaks through the valve body’s drain outlet. If the medium drains completely, the seal is intact. If pressure is consistently discharged, the valve is leaking and requires appropriate corrective action.